| D | F | E | ![]() |
| index Ma | previous | next | |
Ma G, Brady WJ, Pollack M, Chan TC
| Authors |
Electrocardiographic manifestations: Digitalis toxicity(1). | Title |
J Emerg Med 2001 Feb;20(2):145-152
| Source |
| Digitalis, Digoxin, ECG
| Index terms |
| Toxicity from the digitalis family of cardiac glycoside medications remains common. Successful treatment depends on early recognition; however, the diagnosis of potentially life-threatening toxicity remains difficult because the clinical presentation is often nonspecific and subtle. The hallmark of cardiac toxicity is increased automaticity coupled with concomitant conduction delay. Though no single dysrhythmia is always present, certain aberrations such as frequent premature ventricular beats, bradydysrhythmias, paroxysmal atrial tachycardia with block, junctional tachycardia, and bidirectional ventricular tachycardia are common. Treatment depends on the clinical condition rather than serum drug level. Management varies from temporary withdrawal of the medication to administration of digoxin-specific Fab fragments for
life-threatening cardiovascular compromise.
| Abstract |
| Article
| Type |
| Disclaimer: The producers of these references take care to avoid errors but cannot be hold responsible for inaccuracies. Also, knowledge is constantly changing and the reader is advised to search carefully for the most recent and relevant studies.
| |
page generated by mib |